Experimental Study of 220 VAC Fan Performance Using a 12 VDC Battery Power Supply with a Sine Wave Invender

Authors

  • zimmy Rozak Teknik Mesin Unim
  • Achmad Rijanto Teknik Mesin Unim
  • Nuril Ahmad Teknik Mesin Unim

DOI:

https://doi.org/10.59890/ijatss.v4i8.280

Keywords:

Backup Energy, Sinusoidal Inverter, AC Fan, Motor Performance, DC-AC System

Abstract

The public's dependence on air conditioning devices such as conventional fans triggers the need for a reliable backup power supply system during power outages. This study explores the implementation of a 12 VDC battery-based standalone power supply system converted using a pure sine wave inverter to operate a 220 VAC fan. Through experimental methods, the focus of testing is directed at analyzing electrical characteristics, motor rotation stability, and the resulting energy conversion efficiency. The test results show that the inverter is capable of transforming direct voltage into fan voltage and can operate optimally at maximum speed with an average current consumption of 5.6 A. In addition, this system is able to maintain an operational duration of up to 1.45 hours before the battery voltage reaches the critical discharge limit. The decline in mechanical performance of the fan is proven to be insignificant compared to when using the PLN electricity grid. This research concludes that the integration of a pure sinusoidal inverter is effective in maintaining the performance of the fan induction motor from the risk of overheating and efficiency degradation due to wave distortion

References

Gunawan, F., & Setiawan, B. (2023). Analisis Harmonisa dan Efisiensi Energi pada Inverter Pure Sine Wave untuk Beban Rumah Tangga. Jurnal Teknik Elektro dan Komputer, 12(1), 45-52. Akses Portal Jurnal Unsrat.

Hardi, S., & Siregar, I. (2021). Studi Komparasi Karakteristik Beban Induktif pada Inverter Modified Sine Wave dan Pure Sine Wave Berbasis Aki 12 VDC. Jurnal Energi dan Kelistrikan UMSU, 13(2), 115-122.

Kristiawan, H., & Utomo, S. (2022). Rancang Bangun Inverter Satu Fasa Pure Sine Wave Menggunakan Kontroler EGS002 untuk Catu Daya Cadangan Darurat. Jurnal Arus Elektro Indonesia, 8(2), 34-40. Akses Jurnal Polije.

Pradana, A. Y., & Wibowo, T. (2024). Analisis Perbandingan Unjuk Kerja Motor Induksi Satu Fasa pada Suplai Tegangan PLN dan Inverter SPWM. Jurnal Elektronika Daya Komersial, 5(3), 88-95. Akses ResearchGate.

Syahputra, R., & Handayani, M. (2025). Pengaruh Distorsi Gelombang Tegangan Inverter terhadap Manajemen Termal Beban Induktif Domestik. Jurnal Sains dan Teknologi Kelistrikan, 16(1), 12-19. Akses Jurnal Garuda.

Downloads

Published

2026-09-05

Issue

Section

Articles